Storage, Installation, Use And Maintenance Of Wafer-type Fluorine-lined Butterfly Valves

Publish Time: Author: Site Editor Visit: 5

Lined Butterfly Valve Storage: Before the valve is used, the disc should be in an unopened state and placed in a ventilated or dry warehouse. Stacking and outdoor storage are strictly prohibited. The valve ends should be sealed with plugs to prevent dust and impurities from entering the valve to ensure the cleanliness of the valve.
Installation: When installing the wafer-type fluorine-lined butterfly valve, carefully check whether the valve logo and certificate meet the requirements of the pipeline. Installation can only be carried out after everything is correct. The valve sealing surface cannot be damaged during the installation process. When the lining and the pipeline are connected, do not add gaskets. For metal pipeline connections, you can use corresponding gaskets to ensure that the sealing surface is not worn. Correct installation and operation of the wafer-lined fluorine butterfly valve
When the wafer-type butterfly valve is in use, it should be fully opened or fully closed. Do not adjust the flow to use it. It is not allowed to be used under negative pressure conditions. When using this valve, it should be squared. If a fault is found, it should be stopped and the cause should be eliminated.

Storage, Installation, Use And Maintenance Of Wafer-type Fluorine-lined Butterfly Valves