Common Troubleshooting Of Ptfe Lined Valves
Lined Valve is a valve product that uses PTFE lining material. If it fails during use, it will affect the normal working efficiency, so it is particularly important to deal with common faults in a timely manner.
1. Valve body leakage:
Cause:
1. The valve body has sand holes or cracks,
2. The valve body is cracked during welding,
Treatment:
1. Polish the suspected cracks and etch them with 4% nitric acid solution. If there are cracks, they can be displayed,
2. Dig and repair the cracks.
PTFE lining valve manufacturer
2. The valve stem and the threaded nut that matches it are damaged or the valve stem head is broken, and the valve stem is bent:
Cause:
1. Improper operation, excessive force on the switch, failure of the limit device, and failure of the over-torque protection.
2. The thread is too loose or too tight.
3. Too many operations and too long service life.
Treatment:
1. Improve the operation, do not use too much force; check the limit device and the over-torque protection device.
2. Select the appropriate material and the assembly tolerance meets the requirements.
3. Replace the spare parts.
3. Leakage on the joint surface of the valve cover:
Reason:
1. The bolts are not tightened enough or are tightened unevenly.
2. The gasket does not meet the requirements or the gasket is damaged.
3. The joint surface is defective.
Treatment:
1. Tighten the bolts or make the gap between the door cover flange consistent.
2. Replace the gasket.
3. Disassemble and repair the sealing surface of the door cover.